Highest Density Solution: Complete 120kW System Only 62"
Tall
Constant Current, Resistance, Voltage, Power, Pulse
Operation Below 1 Volt at HighCurrent Amps
Synchronized Paralleling Creates Larger Systems Controlled
as a Single Unit
Automated Flow Regulation toPrevent Condensation
Modular Design Using StandardBuilding Blocks
Low Water Flow (3gpm @ 10‘C / 12kW)
Self Configuring Based on the Number of Slaves in Use
Range Switching for Increased Resolution and Accuracy |
| Water
Cooled Modules are rated at 12KW with a selection of voltage
and current ratings applicable to the testrequirements
i.e. 50V, 100V, 400V, and 800V modules. The master programs
itself and the slaves follow. The masterand slave modules
may be arrayed in a rack to create specific systems for
the application up to 120KW/Rack.Standard racks are 44
or 60 high x 22 wide x 36 deep.
|
|
Constant Current:0
to selected full scale currentProg. Accuracy:±0.5%
of selected full scaleRegulation:±0.5% of selected
full scaleResolution:1/4000 of selected full scaleConstant
Resistance:Constant Resistance mode operates in Amps/Volt,
or entered in ohmsProg. Accuracy:±3% of selected
full scaleRegulation:±1% of selected full scaleResolution:1/4000
of selected full scaleConstant Voltage:0 to selected selected
full scaleProg. Accuracy:±0.5% of selected full
scaleRegulation:±0.2% of selected full scaleResolution:1/4000
of selected full scaleConstant Power:0 to full scale powerProg.
Accuracy:±3% of full scaleRegulation:±3%
of full scaleResolution(IEEE):0.25% of full scale power
Ext.
Prog:0 to 10 Volts input yields 0 to selected full scale
loading in alloperating modes.Input Impedance:330k OhmsProg.
Response:Limited by internal adjustableslew rate limiter
Frequency:0.06Hz to 3.33kHzAccuracy:0.1%Duty Cycle:0 -
100%(IEEE)Accuracy:0.1%Adjustable Slew Rate:Max:0 to full
scale in 50΅SMin:0 to full scale in 10mS
|
Current Sample Output:Scaling:10 Volts = selected full
scaleAccuracy:±0.5% of selected full scaleSync
Output:Timing:Synchronous with pulse generator.Output:Sink
with 10k pull up to +15V
Current Limit:Range:0 - 105% of selected full scaleResolution:0.5%
of selected full scaleVoltage Limit:Range:0 - 105% of
selected full scaleResolution:0.5% of selected full scalePower
Limit:Range:0 - 105% of full scaleResolution:50 WattsThermal:Load
disconnect at internaltemperature of 70°CUndervoltage:Load
inhibited at less than0.5 Volt, when enabled
Current:Resolution:1/4000 of Selected Full ScaleAccuracy(Range):±0.5%
±1 DigitVoltage:Resolution:1/4000 of Selected Full
ScaleAccuracy(Range):±0.5% ±1DigitPower:Resolution:3
WattsAccuracy:0.50%
AC Input:User Selectable 120VAC, 240VAC, ±10%,
48 - 62 Hz @ 350WOther voltages available. Consult FactoryAmbient
Temp:0°C to 40°C
|