| Features |
 |
 |
•
High
Speed Adjustable Slew Ratete
•
Front
Panel or Remote Control
•
19
inch Rack Mount - 5U high
•
Pulse
Load Shaping
•
Full Range Switching
•
Quiet Variable Speed Fans |
| General
Specifications |
|
 |
|
OPERATION
Constant Current: 0 to selected full scale
current
Prog. Accuracy
(Range): (high/med) ranges: ±0.25%
(low) range: ±0.5%
Regulation: ±0.1% of selected full scale
Resolution(IEEE): 1/4000 of selected full scale
Constant Resistance: Constant Resistance
mode
operates in Amps/Volt, IEEE
units entered in ohms or A/V
Prog. Accuracy: ±3% of selected full scale
Regulation: ±3% of selected full scale
Resolution(IEEE): 1/4000 of selected full scale
Constant Voltage: 0 to selected selected full
scale
Prog. Accuracy
(Range):
(high/med) ranges:±0.25%
(low): ± 0.5%
Regulation: ±0.15% of selected full scale
Resolution(IEEE): 1/4000 of selected full scale
Constant Power: 0 to full scale power
Prog. Accuracy: ±3% of full scale
Regulation: ±3% of full scale
Resolution(IEEE): 0.25% of full scale power
ANALOG MODE
Ext. Prog: 0 to 10 Volts input yields 0 to
selected full
scale loading in all
operating modes.
Input Impedance: 330k Ohms
Prog. Response: Limited by internal
adjustable slew rate limiter
PULSE MODE
Frequency: 0.06Hz to 20kHz
Accuracy: 0.1%
Duty Cycle: 0 - 100%(IEEE),10 -
90%(Analog)
Accuracy: 0.1%
Adjustable Slew Rate:
Max: 0 to full scale in 10µS
Min: 0 to full scale in 10mS
OUTPUT SIGNALS
Current Sample Output: |
Scaling: 10 Volts = selected full scale
Accuracy: ±0.5% of selected full scale
Sync Output:
Timing: Synchronous with pulse
generator.
Output: Sink with 10k pull up to
+15V PROTECTION
Current Limit:
Analog Models: Approximately 105% of
selected full
scale current
Range(IEEE): 0 - 105% of selected full
scale
Resolution(IEEE): 0.5% of selected full scale
Voltage Limit:
Analog Models: Load disconnect at 105% of
selected full scale voltage
Range(IEEE): 0 - 105% of selected full
scale
Resolution(IEEE): 0.5% of selected full scale
Power Limit:
Analog Models: Approximately 4250 Watts
Range(IEEE): 0 - 4200 Watts
Resolution(IEEE): 20 Watts
Thermal: Load disconnect at internal
temperature of 105°C
Undervoltage: Load inhibited at less than1
Volt, when enabled IEEE-488
READBACKS
Current:
Resolution: 1/4000 of Selected Full Scale
Accuracy(Range): (High/Med): ±0.25% ±1 Digit
(Low): ±0.5% ±1 Digit
Voltage:
Resolution: 1/4000 of Selected Full Scale
Accuracy(Range): (High/Med): ±0.25% ±1 Digit
(Low): ±0.5% ±1Digit
Power:
Resolution: 1 Watt
Accuracy: 0.50% MISCELLANEOUS
AC Input: User Selectable 100VAC,
120VAC, 200VAC, 240VAC, ±10%, 48 - 62 Hz @ 350W
Ambient Temp: 0°C to 40°C |
| |
| SAFE OPERATING
AREA & SPECIFICATIONS |
 |
| The RBL 488
Dynaload Series features 400, 800, 2000 and 4000 watt models
with wide range IEEE 488 computer programming. Individual
models are designed for low voltage high current application
up to 1000 amperes at fractions of a volt whereas other
models are designed for midrange applications and high voltage
applications up to 1000 volts. Equivalent RBL Dynaloads
are available with RS 232 and Analog programming for laboratory
as well as production applications. All models include easy
to apply master slave parallel capabilities and all higher
power models incorporate variable speed forced air cooling
to assure a quiet environment. |
| RBL488
50-1000-4000 |
|
|
OPERATING
RANGES (FULL SCALES)
Voltage: 10 Volts, 20 Volts, 50 Volts
Current: 100 Amps, 500 Amps, 1000 Amps
Power: 4000 Watts
Short Circuit: 0.0004 Ohms max.
CONSTANT RESISTANCE RANGES
High Ohms Mode
Range 100A 500A 1000A
10V 0-5 A/V 0-25 A/V 0-50 A/V
20V 0-2.5 A/V 0-12.5 A/V 0-25 A/V
50V 0-1 A/V 0-5 A/V 0-10 A/V
Low Ohms Mode
Range 100A 500A 1000A
10V 0-50 A/V 0-250 A/V 0-500 A/V
20V 0-25 A/V 0-125 A/V 0-250 A/V
50V 0-10 A/V 0-50 A/V 0-100 A/V |
 |
| RBL488
100-600-4000 |
 |
|
OPERATING
RANGES (FULL SCALES)
Voltage: 10 Volts, 50 Volts, 100 Volts
Current: 20 Amps, 200 Amps, 600 Amps
Power: 4000 Watts
Short Circuit: 0.003 Ohms max.
CONSTANT RESISTANCE RANGES
High Ohms Mode
Range 20A 200A 600A
10V 0-1 A/V 0-10 A/V 0-30 A/V
50V 0-.2 A/V 0-2 A/V 0-6 A/V
100V 0-1 A/V 0-1 A/V 0-3 A/V
Low Ohms Mode
Range 20A 200A 600A
10V 0-10 A/V 0-100 A/V 0-300 A/V
50V 0-2 A/V 0-20 A/V 0-60 A/V
100V 0-1 A/V 0-10 A/V 0-30 A/V |
 |
| RBL488 400-600-4000 |
 |
|
OPERATING
RANGES (FULL SCALES)
Voltage: 20 Volts, 200 Volts, 400 Volts
Current: 20 Amps, 200 Amps, 600 Amps
Power: 4000 Watts
Short Circuit: 0.010 Ohms max.
CONSTANT RESISTANCE RANGES
High Ohms Mode
Range 20A 200A 600A
20V 0-.5 A/V 0-5 A/V 0-15 A/V
200V 0-.05 A/V 0-5 A/V 0-1.5 A/V
400V 0-.025 A/V 0-.25 A/V 0-.75 A/V
Low Ohms Mode
Range 20A 200A 600A
20V 0-5 A/V 0-50 A/V 0-150 A/V
200V 0-.5 A/V 0-2.5 A/V 0-15 A/V
400V 0-.25A/V 0-2.5 A/V 0-7.5 A/V |

|
| RBL488 600-200-4000 |
 |
OPERATING
RANGES (FULL SCALES)
Voltage: 20 Volts, 200 Volts, 600 Volts
Current: 2 Amps, 20 Amps, 200 Amps
Power: 4000 Watts
Short Circuit: 0.035 Ohms max. CONSTANT
RESISTANCE RANGES
High Ohms Mode
Range 2A 20A 200A
20V 0-.05 A/V 0-.5 A/V 0-5A/V
200V 0-.005 A/V 0-.05 A/V 0-.5 A/V
600V 0-.0016 A/V 0-.016 A/V 0-.166 A/V
Low Ohms Mode
Range 2A 20A 200A
20V 0-.5 A/V 0-5 A/V 0-50 A/V
200V 0-.05 A/V 0-.5 A/V 0-5 A/V
600V 0-.016 A/V 0-.166 A/V 0-1.666A/V
|
 |
| RBL488 1000-100-3000 |
 |
OPERATING
RANGES (FULL SCALES)
Voltage: 100 Volts, 500 Volts, 1000 Volts
Current: 2 Amps, 20 Amps, 100 Amps
Power: 3000 Watts
Short Circuit: 0.033 Ohms max. CONSTANT
RESISTANCE RANGES
High Ohms Mode
Range 2A 20A 100A
100V 0-.01 A/V 0-.10 A/V 0-.50 A/V
500V 0-.002 A/V 0-.02 A/V 0-.10 A/V
1000V 0-.001 A/V 0-.01 A/V 0-.05 A/V
Low Ohms Mode
Range 2A 20A 100A
100V 0-.10 A/V 0-1.0 A/V 0-5 A/V
500V 0-.02 A/V 0-.20 A/V 0-1.0 A/V
1000V 0-.01 A/V 0-.10 A/V 0-.50 A/V |
 |
| 4000W Outline |
 |
| 
|
| This
data sheet is believed to be correct at time of publication
and Transistor Devices, Inc. accepts no responsibility for
consequences from printing errors or inaccuracies. Specifications
are subject to change without notice. |