RBL 488 2000 Series
TDI
Features

High Speed Adjustable Slew Rate
Front Panel or Remote Control
19 Rack Mount - 3U High
Pulse Load Shaping
Full Range Switching
Quiet Variable Speed Fans

Genera l Specifications  

OPERATION
Constant Current: 0 to selected full scale current
Prog. Accuracy
(Range): (high/med) ranges: ±0.25%
(low) range: ±0.5%
Regulation: ±0.1% of selected full scale
Resolution(IEEE): 1/4000 of selected full scale
Constant Resistance: Constant Resistance mode
operates in Amps/Volt, IEEE
units entered in ohms or A/V
Prog. Accuracy: ±3% of selected full scale
Regulation: ±3% of selected full scale
Resolution(IEEE): 1/4000 of selected full scale
Constant Voltage: 0 to selected selected full scale
Prog. Accuracy
(Range):
(high/med) ranges:±0.25%
(low): ± 0.5%
Regulation: ±0.15% of selected full scale
Resolution(IEEE): 1/4000 of selected full scale
Constant Power: 0 to full scale power
Prog. Accuracy: ±3% of full scale
Regulation: ±3% of full scale
Resolution(IEEE): 0.25% of full scale power

ANALOG MODE
Ext. Prog: 0 to 10 Volts input yields 0 to
selected full
scale loading in all
operating modes.
Input Impedance: 330k Ohms
Prog. Response: Limited by internal
adjustable slew rate limiter
PULSE MODE
Frequency: 0.06Hz to 20kHz
Accuracy: 0.1%
Duty Cycle: 0 - 100%(IEEE),10 - 90%(Analog)
Accuracy: 0.1%
Adjustable Slew Rate:
Max: 0 to full scale in 10µS
Min: 0 to full scale in 10mS

OUTPUT SIGNALS
Current Sample Output:
Scaling: 10 Volts = selected full scale

Accuracy: ±0.5% of selected full scale
Sync Output:
Timing: Synchronous with pulse
generator.
Output: Sink with 10k pull up to +15V

PROTECTION
Current Limit:
Analog Models: Approximately 105% of
selected full
scale current
Range(IEEE): 0 - 105% of selected full scale
Resolution(IEEE): 0.5% of selected full scale
Voltage Limit:
Analog Models: Load disconnect at 105% of
selected full scale voltage
Range(IEEE): 0 - 105% of selected full scale
Resolution(IEEE): 0.5% of selected full scale
Power Limit:
Analog Models: Approximately 4250 Watts
Range(IEEE): 0 - 4200 Watts
Resolution(IEEE): 20 Watts
Thermal: Load disconnect at internal
temperature of 105°C
Undervoltage: Load inhibited at less than1
Volt, when enabled

IEEE-488 READBACKS
Current:
Resolution: 1/4000 of Selected Full Scale
Accuracy(Range): (High/Med): ±0.25% ±1 Digit
(Low): ±0.5% ±1 Digit
Voltage:
Resolution: 1/4000 of Selected Full Scale
Accuracy(Range): (High/Med): ±0.25% ±1 Digit
(Low): ±0.5% ±1Digit
Power:
Resolution: 1 Watt
Accuracy: 0.50%

MISCELLANEOUS
AC Input: User Selectable 100VAC,
120VAC, 200VAC, 240VAC,
±10%, 48 - 62 Hz @ 350W
Ambient Temp: 0°C to 40°C
 
SAFE OPERATING AREA & SPECIFICATIONS
The RBL 488 2000 watt Dynaload has all of the features and capabilities of it's 4000 watt big brother in a smaller, lighter and economical 3U high package. The front panel displays and programming are identical with other RBL 488 Dynaload Models for simplified test system applications. All models include simplified master slave interconnection, full range switching and variable speed fans to assure quiet operation.
RBL488 50-400-2000

OPERATING RANGES (FULL SCALES)
Voltage: 10 Volts, 20 Volts, 50 Volts
Current: 20 Amps, 200 Amps, 400 Amps
Power: 2000 Watts
Short Circuit: 0.001 Ohms max.

CONSTANT RESISTANCE RANGES
High Ohms Mode
Range 20A 200A 400A
10V 0-1A/V 0-10A/V 0-20A/V
20V 0-.5A/V 0-5A/V 0-10A/V
50V 0-.2A/V 0-2A/V 0-4A/V
Low Ohms Mode
Range: 20A 200A 400A
10V 0-10A/V 0-100A/V 0-200A/V
20V 0-5A/V 0-50A/V 0-100A/V
50V 0-2A/V 0-20A/V 0-40A/V

RBL488 100-300-2000

OPERATING RANGES (FULL SCALES)
Voltage: 10 Volts, 50 Volts, 100 Volts
Current: 20 Amps, 200 Amps, 300 Amps
Power: 2000 Watts
Short Circuit: 0.005 Ohms max.

CONSTANT RESISTANCE RANGES
High Ohms Mode
Range 20A 200A 300A
10V 0-1 A/V 0-10 A/V 0-15 A/V
50V 0-.2 A/V 0-2 A/V 0-3 A/V
100V 0-.1 A/V 0-1 A/V 0-1.5 A/V
Low Ohms Mode
Range 20A 200A 300A
10V 0-10 A/V 0-100 A/V 0-150 A/V
50V 0-2 A/V 0-20 A/V 0-30 A/V
100V 0-A/V 0-10 A/V 0-15 A/V

RBL488 400-300-2000

OPERATING RANGES (FULL SCALES)
Voltage: 20 Volts, 200 Volts, 400 Volts
Current: 20 Amps, 200 Amps, 300 Amps
Power: 2000 Watts
Short Circuit: 0.010 Ohms max.

CONSTANT RESISTANCE RANGES
High Ohms Mode
Range 20A 200A 300A
20V 0-.5 A/V 0-5 A/V 0-7.5 A/V
200V 0-.05 A/V 0-5 A/V 0-.75 A/V
400V 0-.025 A/V 0-.25 A/V 0-.375 A/V
Low Ohms Mode
Range 20A 200A 300A
20V 0-5 A/V 0-50 A/V 0-75 A/V
200V 0-.5 A/V 0-2.5 A/V 0-7.5 A/V
400V 0-.25A/V 0-2.5 A/V 0-3.75 A/V

RBL488 600-100-2000
OPERATING RANGES (FULL SCALES)
Voltage: 20 Volts, 200 Volts, 600 Volts
Current: 2 Amps, 20 Amps, 100 Amps
Power: 2000 Watts
Short Circuit: 0.035 Ohms max.

CONSTANT RESISTANCE RANGES
High Ohms Mode
Range 2A 20A 100A
20V 0-.05 A/V 0-.5 A/V 0-2.5 A/V
200V 0-.005 A/V 0-.05 A/V 0-.25 A/V
600V 0-.0016 A/V 0-.016 A/V 0-.083 A/V
Low Ohms Mode
Range 2A 20A 100A
20V 0-.5 A/V 0-5 A/V 0-25 A/V
200V 0-.05 A/V 0-.5 A/V 0-2.5 A/V
600V 0-.016 A/V 0-.166 A/V 0-.833A/V
2000W Outline

 

This data sheet is believed to be correct at time of publication and Transistor Devices, Inc. accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice.
 
   

©2005 WonATech Co.,Ltd. • T: 02)578-6516  • F: 02)576-2635• sales@wonatech.com Contact