TDI
Features

• High Speed Adjustable Slew Rate
• Front Panel or Remote Control
• Operation to LessThan 200mv
• Pulse Load Shaping
• Full Range Switching
• IEEE-488 Standard,RS-232 Available

General Specifications  
OPERATION
Constant Current:0 to selected full scale currentProg. Accuracy
(Range):(high/med) ranges: ±0.25% (low) range: ±0.5%
Regulation:±0.1% of selected full scal eResolution(IEEE):1/4000 of selected full scaleConstant Resistance:Constant Resistance mode operates in Amps/Voltunits entered in ohms or A/VProg. Accuracy:±3% of selected full scaleRegulation:±3% of selected full scaleResolution(IEEE):1/4000 of selected full scaleConstant Voltage: 0 to selected selected full scaleProg. Accuracy(Range):(high/med) ranges:±0.25%(low):± 0.5%Regulation:±0.15% of selected full scaleResolution(IEEE):1/4000 of selected full scaleConstant Power:0 to full scale powerProg. Accuracy:±3% of full scaleRegulation:±3% of full scaleResolution(IEEE):0.25% of full scale power


ANALOG MODE
Ext. Prog:0 to 10 Volts input yields 0 to selected full scale loading in alloperating modes.Input Impedance:330k OhmsProg. Response:Limited by internaladjustable slew rate limiter

PULSE MODE
Frequency:0.06Hz to 20kHzAccuracy:0.1%Duty Cycle:0 - 100%(IEEE),10 - 90% (Analog) Accuracy:0.1%Adjustable Slew Rate:Max:0 to full scale in 10΅SMin:0 to full scale in 10mS

 

OUTPUT SIGNALS
Current Sample Output:Scaling:10 Volts = selected full scaleAccuracy:±0.5% of selected full scaleSync Output:Timing:Synchronous with pulsegenerator.Output:Sink with 10k pull up to +15V

PROTECTION
Current Limit:Analog Models:Approximately 105% of selected fullscale currentRange(IEEE):0 - 105% of selected full scaleResolution(IEEE):0.5% of selected full scaleVoltage Limit:Analog Models:Load disconnect at 105% of selected full scale voltageRange(IEEE):0 - 105% of selected full scaleResolution(IEEE):0.5% of selected full scalePower Limit:Analog Models:Approximately 4250 WattsRange(IEEE):0 - 4200 WattsResolution(IEEE):20 WattsThermal:Load disconnect at internal temperature of 105°CUndervoltage:Load inhibited at less than1 Volt, when enabled

IEEE-488 READBACKS
Current:Resolution:1/4000 of Selected Full ScaleAccuracy(Range): (High/Med): ±0.25% ±1 Digit(Low): ±0.5% ±1 DigitVoltage:Resolution:1/4000 of Selected Full ScaleAccuracy(Range):(High/Med): ±0.25% ±1 Digit(Low): ±0.5% ±1DigitPower:Resolution:1 WattAccuracy:0.50%

MISCELLANEOUS

AC Input:User Selectable 100VAC,120VAC, 200VAC, 240VAC,±10%, 48 - 62 Hz @ 350WAmbient Temp:0°C to 40°C
 
SAFE OPERATING AREA & SPECIFICATIONS 
Even more compact than the 800W RBL model, the 400W model is the newest addition to theRBL family. The RBL488 400 watt models offer full size load capabilities in a VERY compact size.The RBL488 400 Watt model will sink up to 60 amps for 400 watt requirements but neversacrifice accuracy at lighter load levels. With its compact size and convenient carrying handle,this model is an excellent choice for portable applications and miscellaneous fieldwork.
RBL488 100-60-400

OPERATING MODES
Constant Current:0 to selected full scale currentProgram Accuracy:60A, 30A and 6A ranges +/-0.5Regulation:+/- 0.1% of full scaleResolution:1/4000 of selected full scaleConstant Resistance:Operates in Ohms or Amps/Volt (selectable)Program Accuracy:+/- 3% of full scaleRegulation:+/- 3% of full scaleResolution:1/4000 of selected full scaleHigh Ohms ModeRange 6A30A60A10V0-.3 A/V0-1.5 A/V 0-3 A/V50V0-.06 A/V0-.3 A/V0-.6 A/V100V0-.03 A/V0-.15 A/V0-.3 A/VLow Ohms ModeRange6A30A60A10V0-3 A/V0-15 A/V0-30 A/V50V0-.6 A/V0-3 A/V0-6 A/V100V0-.3A/V0-1.5 A/V0-3 A/VConstant Voltage:0 to selected full scale currentProgram Accuracy:100V, 50V and 10V ranges +/-0.5Regulation:+/- 0.15% of full scaleResolution:1/4000 of selected full scaleConstant Power:0 – 400 WattsProgram Accuracy:+/- 4% of full scaleRegulation:+/- 4% of full scaleResolution:0.1 WattsShort circuit:0.05 Ohms Max.

PULSE MODES
Operation:Pulse added on top of D.C. setpointMay be used in conjunction withexternal programmingFrequency:.01 to 3333Hz.Accuracy:.1%Duty Cycle:0 – 100%Accuracy:.1%Slew Rate:10 micro seconds to .4 seconds

OUTPUT SIGNALS
Current Sample OutputScaling:10 Volts = Selected full scale currentAccuracy:.5% of full scaleSync Output:Timing:Synchronous with pulse generatorOutput:Sink with 10K ohm up to +15VDC

RBL488 400-60-400

OPERATING MODES
Constant Current:0 to selected full scale currentProgram Accuracy:60A, 30A and 6A ranges +/-0.5Regulation:+/- 0.1% of full scaleResolution:1/4000 of selected full scaleConstant Resistance:Operates in Ohms orAmps/Volt (selectable)Program Accuracy:+/- 3% of full scaleRegulation:+/- 3% of full scaleResolution:1/4000 of selected full scaleHigh Ohms ModeRange 6A30A60A20V0-.15 A/V0-.75 A/V 0-1.5 A/V200V0-.015 A/V0-.075 A/V0-.15 A/V400V0-.0075 A/V0-.0375 A/V.075 A/VLow Ohms ModeRange6A30A60A20V0-1.5 A/V0-7.5 A/V0-15 A/V200V0-.15 A/V0-.75 A/V0-1.5 A/V400V0-.075A/V0-.375 A/V0-.75 A/VConstant Voltage:0 to selected full scale currentProgram Accuracy:400V, 200V and 20V ranges +/-0.5Regulation:+/- 0.15% of full scaleResolution:1/4000 of selected full scaleConstant Power:0 – 400 WattsProgram Accuracy:+/- 4% of full scaleRegulation:+/- 4% of full scaleResolution:0.1 WattsShort circuit:0.05 Ohms Max.

PULSE MODES
Operation:Pulse added on top of D.C. setpoint. May be used in conjunction with external programmingFrequency:.01 to 3333Hz.Accuracy:.1%Duty Cycle:0 – 100%Accuracy:.1%Slew Rate:10 micro seconds to .4 seconds

OUTPUT SIGNALS
Current Sample OutputScaling:10 Volts = Selected full scale currentAccuracy:.5% of full scaleSync Output:Timing:Synchronous with pulse generatorOutput:Sink with 10K ohm up to +15VDC


 
This data sheet is believed to be correct at time of publication and Transistor Devices, Inc. accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice.
 
   