RBL-Small: For use
with RBL & RBL488 800 Watt models
(#4 Braid, 4’ Long) RBL-Large: For use with RBL & RBL488
2000/4000 Watt
models (1/O Braid, 4’ Long) RBL-HV: For use with RBL & RBL488
1000 Volt models
(#4 Braid, 4’ Long, High Voltage Connectors)
Custom lengths available, please consult factory.
Slides
LAB
VIEW DRIVERS
Note: All slides are locking slides
RBL-Slides: For use with the RBL & RBL488 Series
WCL-MCL-Slides: For use with the WCL & MCL Series
DLVP-Slides: For use with DLVP 3000 Watt models
All other models: Please contact factory
Lab view drivers are available for the WCL488, RBL488
and MCL488 Series. They can be requested via
telephone or downloaded from our web site
RBL-Rack
WCS
MOUNTING KITS
51/4" sub-rack housing used
for mounting up to two 800W
RBL units in a standard 19" equipment rack.
(See Page 27 for outline)
This kit is included with all slave units
and consists of
all plumbing and bus bars neccesary to install additional
slaves in an existing system. It is also available as
an accessory.
Constant
resistance Interface (SPS-2763)
This
option utilizes a 0 to 10 volt analog signal to program
any Dynaload in constant resistance mode. The analog program
signal
corresponds to the zero to full scale constant resistance
setting to which the unit is configured. A TTL signal controls
the toggle between constant current programming and constant
resistance programming.
Constant Power
Interface (CPI-XXX)
This
option utilizes a 0 to 10 volt analog signal to program
any Dynaload in constant power mode. The analog program
signal corresponds to the zero to full scale constant power
setting to which the unit is configured. A TTL signal controls
the toggle between constant current programming and constant
power programming.
NOTE: XXX denotes maximum power level of the model to which
this option should be configured.
Constant Power
Interface (CVI-XXX)
This
option utilizes a 0 to 10 volt analog signal to program
any Dynaload in constant voltage mode. The analog program
signal corresponds to the zero to full scale constant
voltage setting to which the unit is configured. A TTL
signal controls the toggle between constant current programming
and constant voltage programming.
* NOTE: XXX denotes maximum power level of the model to
which this option should be configured.
Program Isolator
(SPS-2569)
This
option provides the necessary program isolation when programming
multiple Dynaloads a single source.
This
data sheet is believed to be correct at time of publication
and Transistor Devices, Inc. accepts no responsibility for
consequences from printing errors or inaccuracies. Specifications
are subject to change without notice.