Options & Accessories
TDI
Low Inductive Cables with Fusion Lug™ Technology

RBL-Small: For use with RBL & RBL488 800 Watt models
(#4 Braid, 4’ Long)
RBL-Large: For use with RBL & RBL488 2000/4000 Watt
models (1/O Braid, 4’ Long)
RBL-HV: For use with RBL & RBL488 1000 Volt models
(#4 Braid, 4’ Long, High Voltage Connectors)

Custom lengths available, please consult factory.

Slides LAB VIEW DRIVERS

Note: All slides are locking slides
RBL-Slides: For use with the RBL & RBL488 Series
WCL-MCL-Slides: For use with the WCL & MCL Series
DLVP-Slides: For use with DLVP 3000 Watt models
All other models: Please contact factory

Lab view drivers are available for the WCL488, RBL488
and MCL488 Series. They can be requested via
telephone or downloaded from our web site
RBL-Rack WCS MOUNTING KITS

51/4" sub-rack housing used for mounting up to two 800W
RBL units in a standard 19" equipment rack.
(See Page 27 for outline)

This kit is included with all slave units and consists of
all plumbing and bus bars neccesary to install additional
slaves in an existing system. It is also available as
an accessory.
 
Constant resistance Interface (SPS-2763)
This option utilizes a 0 to 10 volt analog signal to program any Dynaload in constant resistance mode. The analog program signal
corresponds to the zero to full scale constant resistance setting to which the unit is configured. A TTL signal controls the toggle between constant current programming and constant resistance programming.
Constant Power Interface (CPI-XXX)  
This option utilizes a 0 to 10 volt analog signal to program any Dynaload in constant power mode. The analog program signal corresponds to the zero to full scale constant power setting to which the unit is configured. A TTL signal controls the toggle between constant current programming and constant power programming.

NOTE: XXX denotes maximum power level of the model to which this option should be configured.
Constant Power Interface (CVI-XXX)

This option utilizes a 0 to 10 volt analog signal to program any Dynaload in constant voltage mode. The analog program signal corresponds to the zero to full scale constant voltage setting to which the unit is configured. A TTL signal controls the toggle between constant current programming and constant voltage programming.

* NOTE: XXX denotes maximum power level of the model to which this option should be configured.

Program Isolator (SPS-2569)
This option provides the necessary program isolation when programming multiple Dynaloads a single source.
This data sheet is believed to be correct at time of publication and Transistor Devices, Inc. accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice.
 
   
©2003 TDI-Transistor Devices, Inc. • 973.267.1900 • info@tdipower.com Contact