| Features |
 |
 |
•
Modular Loads
•
Economical & Compact
•
Analog Programmable
•
Rack Required (Part# 112479)
|
| General
Specifications-DLM 50-20-100 DIG |
 |
OPERATION
Operating Voltage:3 - 50 Volts
Operating Current:0 - 20 Amps
Power Dissipation:0 - 100 Watts
Ammeter Ranges:0 - 5 Amps • 0 - 20 Amps
Constant Current:0 - 20 Amps
Constant Resistance:0 - 5 A/V
Over Current:24 Amps Max
Power Limit:140 Watts
Response Time:<50µS
Ext. Prog:0 to 10 Volts input yields 0 to full scale
current.
Prog. Accuracy:±1% of setpoint from 10 to100%
of rated current
Meter Accuracy:<±2%
|
MECHANICAL
Module Size:4”W x 5.25”H x 12”D102mm
W x 133mm H x 305mm D
Module Weight:4 lbs. / 1.81kg
Rack Size:19”W x 5.25”H x 11.85”D483mm
W x 133mm H x 301mm D
Rack Weight:20 lbs. / 9.07kg |
| |
DLVP
Series |
 |
 |
|
DLVP
100-300-3000 |
|
|
|
OPERATING
Operating Voltage:3.5 – 100 Volts
Operating Current:0 – 300 Amps
Power Dissipation:0 – 3000 Watts
Voltmeter Ranges:0 – 12 Volts0 – 36
Volts0 – 120 Volts
Ammeter Ranges:0 – 36 Amps0 – 120 Amps0
– 360 Amps
Constant Current:0 – 60 Amps0 – 300
Amps
Constant Resistance:0 – 10 Amps per Volt0
– 30 Amps per Volt
Constant Voltage:0 – 100 Volts
Over Voltage:110 Volts Maximum
Over Current:320 Amps Maximum
Power Limit:3200 Watts Maximum
Frequency Ranges:20 – 200 Hertz100 –
1000 Hertz500 – 5000 Hertz
Pulse Width Range:10 – 100 % Duty Cycle
Slew RateLess than 75uS
Analog Programming0 – 10 Volts input yields
0 to 300 Amps
Programming Accuracy+/- 1% of set point from 10
to 100%of rated current
Current Sample output0 – 10 Volts for 0 to
100% of rated current
Meter Accuracy+/- 3% or better |
MECHANICAL
Size19”W x 8.75”H x 19.18”D
Weight42 lbs. / 19.05kg |
| |
| This
data sheet is believed to be correct at time of
publication and Transistor Devices, Inc. accepts
no responsibility for consequences from printing
errors or inaccuracies. Specifications are subject
to change without notice. |